mode|01.01 Project|01.02 Date|01.03 Building Name|01.04 Building Number|01.05 Street|01.06 City|01.07 State|01.08 Zip|02.01 Ventilation Type|02.02 HVAC Zone Name|02.03 HVAC Model Number|02.04 HVAC Fan Size CFM|02.05 Number of Rooms Serviced by this Zone|02.06 Total Cubic Feet Serviced By This Zone|02.07 List Room Survey Numbers|02.08 HVAC Zone a-AUC|02.09 HVAC Automated Alarms|02.10 Manual Dampers in Ducts|02.11 Thermostat Control by Users|02.12 Thermostat Locks Removed|02.13 Visible Vent Manually Controlled|02.14 System Fans on ALL the time|02.15 System Fans on when public is present|03.01 Number|03.02 Room Name|03.03 Length|03.04 Width|03.05 Height|03.06 Square Feet|03.07 SQFT Height|03.08 Cubic Feet|04.01 Number Of Windows|04.02 Windows Fully Open|04.03 Windows Not Blocked|04.04 Door Open|04.05 Door Not Blocked|04.06 w-AUC|05.01 Exhaust Fan Type|05.02 Number of Exhaust Fans|05.03 Intake Vents Fully Open|05.04 Intake Vents Not Blocked|05.05 Total Exhaust Fans CFM|05.06 Total Exhaust Fans fAUC|06.01 Forced Air Heating|06.02 Forced Air Heating Cooling|06.03 Forced Air Fan Option|06.04 Number of Exhaust Vents|06.05 Exhaust Vents Fully Open|06.06 Exhaust Vents Not Blocked|06.07 Number of Intake Vents|06.08 HVAC Intake Vents Fully Open|06.09 HVAC Intake Vents Not Blocked|06.10 Visual Streamers|06.11 t-AUC|06.12 a-AUC|07.01 Number of UV-C Fixtures|07.02 UV-C Model|07.03 UV-C Total Watts|07.04 UV-C eAUC|07.05 UV C Public View On/Off Indicators|07.07 UV-C Automated Alarms|08.01 Number of Far UV Fixtures|08.02 Far-UV Model|08.03 Far-UV Total Watts|08.04 Far-UV eAUC|08.05 Far UV Public View On/Off Indicators|08.06 Far UV Automated Alarms|09.01 Number of Air Sanitizers|09.02 Air Sanitizers Model|09.03 Air Sanitizers Total CFM|09.04 Air Sanitizers sAUC|09.05 Air Sanitizers Public View On/Off Indicators|09.06 Air Sanitizers Automated Alarms|10.01 Number of PCO/other units|10.02 PCO/other Model|10.03 Claimed effective ep AUC|10.04 Claimed effective ep AUC Test Authority|10.05 PCO/other units Total CFM|10.06 PCO/other units Public View On/Off Indicators|10.07 PCO/other units Automated Alarms|13.01 Occupancy Number|13.02 Room Occupancy Sign Posted|13.03 Public Present During Site Survey|13.04 Data Entered Directly Into Computer|13.05 Printout Attached To Paper Form|14.01 Notes and Observations|15.01 Inspector Name|15.02 Signature Date|16.01 Total AUC|16.02 Large Room Factor|16.03 Final AUC|16.04 Cert Level|16.05 Final AUC Mitigation|16.06 Cert Level Mitigation|16.07 Cert Level Controls Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Fan Coil Unit|each room||0|1|||||||||||B-2|Classroom||||1,073||8584||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Devine Brothers ||0|1|0|0|0|0| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||380|1|||||||||||100|Classroom||||940||7520||||||||||||||||||||||||||||||||||||||||||||||||||21||||||Devine Brothers ||3|1|3|1|3|1| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||470|1|||||||||||106|Classroom||||840||6720||||||||||||||||||||||||||||||||||||||||||||||||||19||||||Devine Brothers ||4|1|4|2|4|2| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||11|1|||||||||||108|Classroom||||828||6624||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Devine Brothers ||0|1|0|0|0|0| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||89|1|||||||||||200|Classroom||||696||5568||||||||||||||||||||||||||||||||||||||||||||||||||5||||||Devine Brothers ||1|1|1|0|1|0| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||231|1|||||||||||202|Classroom||||696||5568||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Devine Brothers ||2|1|2|1|2|1| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||301|1|||||||||||204|Classroom||||696||5568||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Devine Brothers ||3|1|3|1|3|1| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||304|1|||||||||||205|Classroom||||672||5376||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Devine Brothers ||3|1|3|1|3|1| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||200|1|||||||||||206|Classroom||||696||5568||||||||||||||||||||||||||||||||||||||||||||||||||13||||||Devine Brothers ||2|1|2|1|2|1| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||191|1|||||||||||207|Classroom||||696||5568||||||||||||||||||||||||||||||||||||||||||||||||||12||||||Devine Brothers ||2|1|2|1|2|1| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||125|1|||||||||||208|Classroom||||696||5568||||||||||||||||||||||||||||||||||||||||||||||||||8||||||Devine Brothers ||1|1|1|1|1|1| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||178|1|||||||||||209|Classroom||||384||3072||||||||||||||||||||||||||||||||||||||||||||||||||8||||||Devine Brothers ||3|1|3|1|3|1| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||200|1|||||||||||210|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||13||||||Devine Brothers ||2|1|2|1|2|1| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||262|1|||||||||||211|Classroom||||851||6808||||||||||||||||||||||||||||||||||||||||||||||||||17||||||Devine Brothers ||2|1|2|1|2|1| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||280|1|||||||||||212|Classroom||||875||7000||||||||||||||||||||||||||||||||||||||||||||||||||18||||||Devine Brothers ||2|1|2|1|2|1| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||0|1|||||||||||213|Classroom||||875||7000||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Devine Brothers ||0|1|0|0|0|0| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Air Handling Unit|each room||0|1|||||||||||-|AUDITORIUM||||2,793||22344||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Devine Brothers ||0|1.06|0|0|0|0| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||862|1|||||||||||-|Cafeteria||||2,343||18744||||||||||||||||||||||||||||||||||||||||||||||||||53||||||Devine Brothers ||3|1|3|1|3|1| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Air Handling Unit|each room||812|1|||||||||||-|GYM||||3,478||27824||||||||||||||||||||||||||||||||||||||||||||||||||54||||||Devine Brothers ||2|1.06|2.12|1|2|1| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||0|1|||||||||||-|MAIN OFFICE||||552||4416||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Devine Brothers ||0|1|0|0|0|0| Import|Phila-Schools|3/18/2021|Paul Robeson High School|188|||||Univent|each room||64|1|||||||||||-|Student Lounge||||552||4416||||||||||||||||||||||||||||||||||||||||||||||||||4||||||Devine Brothers ||1|1|1|0|1|0|