mode|01.01 Project|01.02 Date|01.03 Building Name|01.04 Building Number|01.05 Street|01.06 City|01.07 State|01.08 Zip|02.01 Ventilation Type|02.02 HVAC Zone Name|02.03 HVAC Model Number|02.04 HVAC Fan Size CFM|02.05 Number of Rooms Serviced by this Zone|02.06 Total Cubic Feet Serviced By This Zone|02.07 List Room Survey Numbers|02.08 HVAC Zone a-AUC|02.09 HVAC Automated Alarms|02.10 Manual Dampers in Ducts|02.11 Thermostat Control by Users|02.12 Thermostat Locks Removed|02.13 Visible Vent Manually Controlled|02.14 System Fans on ALL the time|02.15 System Fans on when public is present|03.01 Number|03.02 Room Name|03.03 Length|03.04 Width|03.05 Height|03.06 Square Feet|03.07 SQFT Height|03.08 Cubic Feet|04.01 Number Of Windows|04.02 Windows Fully Open|04.03 Windows Not Blocked|04.04 Door Open|04.05 Door Not Blocked|04.06 w-AUC|05.01 Exhaust Fan Type|05.02 Number of Exhaust Fans|05.03 Intake Vents Fully Open|05.04 Intake Vents Not Blocked|05.05 Total Exhaust Fans CFM|05.06 Total Exhaust Fans fAUC|06.01 Forced Air Heating|06.02 Forced Air Heating Cooling|06.03 Forced Air Fan Option|06.04 Number of Exhaust Vents|06.05 Exhaust Vents Fully Open|06.06 Exhaust Vents Not Blocked|06.07 Number of Intake Vents|06.08 HVAC Intake Vents Fully Open|06.09 HVAC Intake Vents Not Blocked|06.10 Visual Streamers|06.11 t-AUC|06.12 a-AUC|07.01 Number of UV-C Fixtures|07.02 UV-C Model|07.03 UV-C Total Watts|07.04 UV-C eAUC|07.05 UV C Public View On/Off Indicators|07.07 UV-C Automated Alarms|08.01 Number of Far UV Fixtures|08.02 Far-UV Model|08.03 Far-UV Total Watts|08.04 Far-UV eAUC|08.05 Far UV Public View On/Off Indicators|08.06 Far UV Automated Alarms|09.01 Number of Air Sanitizers|09.02 Air Sanitizers Model|09.03 Air Sanitizers Total CFM|09.04 Air Sanitizers sAUC|09.05 Air Sanitizers Public View On/Off Indicators|09.06 Air Sanitizers Automated Alarms|10.01 Number of PCO/other units|10.02 PCO/other Model|10.03 Claimed effective ep AUC|10.04 Claimed effective ep AUC Test Authority|10.05 PCO/other units Total CFM|10.06 PCO/other units Public View On/Off Indicators|10.07 PCO/other units Automated Alarms|13.01 Occupancy Number|13.02 Room Occupancy Sign Posted|13.03 Public Present During Site Survey|13.04 Data Entered Directly Into Computer|13.05 Printout Attached To Paper Form|14.01 Notes and Observations|15.01 Inspector Name|15.02 Signature Date|16.01 Total AUC|16.02 Large Room Factor|16.03 Final AUC|16.04 Cert Level|16.05 Final AUC Mitigation|16.06 Cert Level Mitigation|16.07 Cert Level Controls Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||300|1|||||||||||1|Classroom||||1350||10800||||||||||||||||||||||||||||||||||||||||||||||||||20||||||Capital Devine Retest ||2|1|2|1|2|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||278|1|||||||||||2|Classroom||||1350||10800||||||||||||||||||||||||||||||||||||||||||||||||||18||||||Capital Devine Retest ||2|1|2|1|2|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||395|1|||||||||||3|Classroom||||1350||10800||||||||||||||||||||||||||||||||||||||||||||||||||26||||||Capital Devine Retest ||2|1|2|1|2|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||425|1|||||||||||4|Classroom||||1296||10368||||||||||||||||||||||||||||||||||||||||||||||||||28||||||Capital Devine Retest ||2|1|2|1|2|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||314|1|||||||||||5|Classroom||||1296||10368||||||||||||||||||||||||||||||||||||||||||||||||||20||||||Capital Devine Retest ||2|1|2|1|2|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||614|1|||||||||||100|Classroom||||960||7680||||||||||||||||||||||||||||||||||||||||||||||||||21||||||Capital Devine Retest ||5|1|5|2|5|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||597|1|||||||||||101|Classroom||||1024||8192||||||||||||||||||||||||||||||||||||||||||||||||||23||||||Capital Devine Retest ||4|1|4|2|4|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||HUV|each room||0|1|||||||||||101A|Instructional Storage||||||||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Capital Devine Retest |||1|0|||| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||560|1|||||||||||102|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||6|1|6|2|6|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||555|1|||||||||||103|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||6|1|6|2|6|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||575|1|||||||||||104|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||6|1|6|2|6|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||618|1|||||||||||105|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||7|1|7|2|7|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||163|1|||||||||||106|Class Area||||625||5000||||||||||||||||||||||||||||||||||||||||||||||||||10||||||Capital Devine Retest ||2|1|2|1|2|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||280|1|||||||||||106A|IT room||||304||2432||||||||||||||||||||||||||||||||||||||||||||||||||6||||||Capital Devine Retest ||7|1|7|2|7|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||155|1|||||||||||107|Class Area||||1050||8400||||||||||||||||||||||||||||||||||||||||||||||||||10||||||Capital Devine Retest ||1|1|1|1|1|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||141|1|||||||||||108|Class Area||||1050||8400||||||||||||||||||||||||||||||||||||||||||||||||||9||||||Capital Devine Retest ||1|1|1|1|1|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||143|1|||||||||||109|Class Area||||625||5000||||||||||||||||||||||||||||||||||||||||||||||||||9||||||Capital Devine Retest ||2|1|2|1|2|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||159|1|||||||||||110|Class Area||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||10||||||Capital Devine Retest ||2|1|2|1|2|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||164|1|||||||||||111|Class Area||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||10||||||Capital Devine Retest ||2|1|2|1|2|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||142|1|||||||||||112|Class Area||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||9||||||Capital Devine Retest ||2|1|2|1|2|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||149|1|||||||||||113|Class Area||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||9||||||Capital Devine Retest ||2|1|2|1|2|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||137|1|||||||||||114|Class Area||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||9||||||Capital Devine Retest ||1|1|1|1|1|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||HUV|each room||0|1|||||||||||114A|Team Planning||||360||2880||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Capital Devine Retest ||0|1|0|0|0|0| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||141|1|||||||||||115|Class||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||9||||||Capital Devine Retest ||2|1|2|1|2|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||0|1|||||||||||118D|Main Office||||150||1200||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Capital Devine Retest ||0|1|0|0|0|0| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||HUV|each room||0|1|||||||||||119A|Instructional Storage||||||||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Capital Devine Retest |||1|0|||| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||305|1|||||||||||119B|Building Engineer's Office||||450||3600||||||||||||||||||||||||||||||||||||||||||||||||||10||||||Capital Devine Retest ||5|1|5|2|5|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||303|1|||||||||||120|Instructional Materials Center||||2520||20160||||||||||||||||||||||||||||||||||||||||||||||||||20||||||Capital Devine Retest ||1|1.06|1.06|0|1|0| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||394|1|||||||||||122|Main Office||||600||4800||||||||||||||||||||||||||||||||||||||||||||||||||13||||||Capital Devine Retest ||5|1|5|2|5|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||301|1|||||||||||122C|Main Office||||130||1040||||||||||||||||||||||||||||||||||||||||||||||||||2||||||Capital Devine Retest ||17|1|17|3|17|3| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||383|1|||||||||||122D|Principal's Office||||216||1728||||||||||||||||||||||||||||||||||||||||||||||||||4||||||Capital Devine Retest ||13|1|13|3|13|3| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||355|1|||||||||||123|Teacher's Dining||||594||4752||||||||||||||||||||||||||||||||||||||||||||||||||13||||||Capital Devine Retest ||4|1|4|2|4|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||298|1|||||||||||123A|Teacher's Lounge||||270||2160||||||||||||||||||||||||||||||||||||||||||||||||||6||||||Capital Devine Retest ||8|1|8|2|8|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||HUV|each room||0|1|||||||||||127|Corridor||||||||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Capital Devine Retest |||1|0|||| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||163|1|||||||||||150|Storage||||360||2880||||||||||||||||||||||||||||||||||||||||||||||||||8||||||Capital Devine Retest ||3|1|3|1|3|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||HUV|each room||0|1|||||||||||153|Corridor||||||||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Capital Devine Retest |||1|0|||| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||152|1|||||||||||165|Gym Office ||||130||1040||||||||||||||||||||||||||||||||||||||||||||||||||2||||||Capital Devine Retest ||9|1|9|2|9|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||153|1|||||||||||184|Examination||||130||1040||||||||||||||||||||||||||||||||||||||||||||||||||2||||||Capital Devine Retest ||9|1|9|2|9|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||622|1|||||||||||200|Classroom||||1350||10800||||||||||||||||||||||||||||||||||||||||||||||||||30||||||Capital Devine Retest ||3|1|3|1|3|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||530|1|||||||||||201|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||6|1|6|2|6|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||HUV|each room||0|1|||||||||||201A|Instructional Storage||||||||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Capital Devine Retest |||1|0|||| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||519|1|||||||||||202|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||6|1|6|2|6|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||434|1|||||||||||203|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||5|1|5|2|5|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||550|1|||||||||||204|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||6|1|6|2|6|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||436|1|||||||||||205|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||5|1|5|2|5|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||500|1|||||||||||206|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||5|1|5|2|5|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||149|1|||||||||||206A|Team Planning||||270||2160||||||||||||||||||||||||||||||||||||||||||||||||||6||||||Capital Devine Retest ||4|1|4|2|4|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||327|1|||||||||||207|Classroom||||945||7560||||||||||||||||||||||||||||||||||||||||||||||||||21||||||Capital Devine Retest ||3|1|3|1|3|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||HUV|each room||0|1|||||||||||208|Corridor||||||||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Capital Devine Retest |||1|0|||| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||509|1|||||||||||208|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||6|1|6|2|6|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||552|1|||||||||||209|Classroom||||625||5000||||||||||||||||||||||||||||||||||||||||||||||||||14||||||Capital Devine Retest ||7|1|7|2|7|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||694|1|||||||||||210|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||8|1|8|2|8|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||531|1|||||||||||211|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||6|1|6|2|6|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||379|1|||||||||||212|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||4|1|4|2|4|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||688|1|||||||||||213|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||7|1|7|2|7|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||382|1|||||||||||214|Classroom||||690||5520||||||||||||||||||||||||||||||||||||||||||||||||||15||||||Capital Devine Retest ||4|1|4|2|4|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||HUV|each room||0|1|||||||||||214A|Instructional Storage||||||||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Capital Devine Retest |||1|0|||| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||370|1|||||||||||215|Classroom||||840||6720||||||||||||||||||||||||||||||||||||||||||||||||||19||||||Capital Devine Retest ||3|1|3|1|3|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||388|1|||||||||||216|Classroom||||805||6440||||||||||||||||||||||||||||||||||||||||||||||||||18||||||Capital Devine Retest ||4|1|4|1|4|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||413|1|||||||||||217|Classroom||||792||6336||||||||||||||||||||||||||||||||||||||||||||||||||18||||||Capital Devine Retest ||4|1|4|1|4|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||328|1|||||||||||218|Classroom||||625||5000||||||||||||||||||||||||||||||||||||||||||||||||||14||||||Capital Devine Retest ||4|1|4|1|4|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||286|1|||||||||||218C|Classroom||||960||7680||||||||||||||||||||||||||||||||||||||||||||||||||19||||||Capital Devine Retest ||2|1|2|1|2|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||862|1|||||||||||219|Classroom||||1800||14400||||||||||||||||||||||||||||||||||||||||||||||||||40||||||Capital Devine Retest ||4|1|4|1|4|1| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||980|1|||||||||||220|Classroom||||1350||10800||||||||||||||||||||||||||||||||||||||||||||||||||30||||||Capital Devine Retest ||5|1|5|2|5|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||342|1|||||||||||221|Classroom||||625||5000||||||||||||||||||||||||||||||||||||||||||||||||||14||||||Capital Devine Retest ||4|1|4|2|4|2| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||HUV|each room||0|1|||||||||||234|Corridor||||||||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Capital Devine Retest |||1|0|||| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||HUV|each room||0|1|||||||||||244|Counselor||||||||||||||||||||||||||||||||||||||||||||||||||||||||0||||||Capital Devine Retest |||1|0|||| Import|Phila-Schools|4/5/2021|Mary McLeod Bethune School|12|||||Unit Ventilator|each room||279|1|||||||||||-|Nurse's Office||||150||1200||||||||||||||||||||||||||||||||||||||||||||||||||3||||||Capital Devine Retest ||14|1|14|3|14|3|